Blast Affected Industrial Unit

Blast Affected Industrial Unit

Radhe Structorepair Pvt Ltd was involved in systematically salvaging “Blast Affected Industrial Unit” located in one of the industrial area. To restore blast affected buildings, it requires a full proof assessment of structural members including through knowledge on it’s behaviour.

The Concerns:

Column got mis-aligned heavily it’s axis

Other local structural members got affected due to blast.

The Repair Methodology:

All affected structural members got evaluated systematically to determine extent of damage and repair strategies. A holistic repair & retrofitting approach implemented. Carried out various tests like, visual inspection, rebound hammer test, UPV test and concrete core test. Following of the methodology adopted jointly with expert structural consultant.

Carried out visual inspection and mapped all defects.

Identified all critical areas.

Carried out detailed analysis of existing structure

Beam strengthening using steel plate connections at soffits

Design for the additional cross section of columns and Column- Beam junction detailing

CFRP wrapping system for composite action and enhancement of load carrying capacity by confinement

The Outcome

Safety and structural integrity of the blast affected building established.

Blast affected structure regained it’s functionality.

Frequent inspection and monitoring of structure post restoration proved success of methodology adopted.